  "schemaVersion": "2.0.0",
  "identity": {
    "slug": "medtronic-percept-pc",
    "manufacturerSlug": "medtronic",
    "name": {
      "value": "Percept PC Neurostimulator",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.medtronic.com/en-us/healthcare-professionals/products/neurological/deep-brain-stimulation/electrical-stimulation-systems/percept-pc-neurostimulator.html",
          "label": "Medtronic — Percept PC Neurostimulator product page"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "modelNumber": {
      "value": "B35200",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "codename": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "aliases": {
      "value": [
        "Percept PC",
        "Medtronic Percept",
        "BrainSense IPG"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.medtronic.com/en-us/healthcare-professionals/products/neurological/deep-brain-stimulation/electrical-stimulation-systems/percept-pc-neurostimulator.html",
          "label": "Medtronic — Percept PC Neurostimulator product page"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "generation": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "predecessorSlug": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "successorSlug": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "tagline": {
      "status": "unknown",
      "sources": [
        {
          "label": "editorial"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "shortDescription": {
      "status": "unknown",
      "sources": [
        {
          "label": "editorial prose"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "longDescription": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "countryOfOrigin": {
      "value": "US",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "releaseDate": {
      "value": "2020-06-24",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        },
        {
          "url": "https://www.accessdata.fda.gov/cdrh_docs/pdf/P960009S219b.pdf",
          "label": "FDA P960009/S219 SSED — Percept PC with BrainSense",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "announcedDate": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "discontinuedDate": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "status": {
      "value": "available",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.medtronic.com/en-us/healthcare-professionals/products/neurological/deep-brain-stimulation/electrical-stimulation-systems/percept-pc-neurostimulator.html",
          "label": "Medtronic — Percept PC Neurostimulator product page"
        }
      ],
      "updatedAt": "2026-05-04"
    }
  },
  "classification": {
    "invasiveness": {
      "value": "invasive",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "modalities": {
      "value": [
        "DBS",
        "LFP"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/cdrh_docs/pdf/P960009S219b.pdf",
          "label": "FDA P960009/S219 SSED — Percept PC with BrainSense",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "primaryModality": {
      "value": "DBS",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "direction": {
      "value": "read-write",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/cdrh_docs/pdf/P960009S219b.pdf",
          "label": "FDA P960009/S219 SSED — Percept PC with BrainSense",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "category": {
      "value": [
        "medical-implant",
        "therapeutic",
        "stimulation"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "formFactor": {
      "value": [
        "cranial-implant"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "intendedUseCases": {
      "value": [
        "deep brain stimulation for Parkinson's disease",
        "deep brain stimulation for essential tremor",
        "deep brain stimulation for dystonia (HDE)",
        "deep brain stimulation for medically refractory OCD (HDE)",
        "chronic LFP sensing of beta-band activity"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/cdrh_docs/pdf/P960009S219b.pdf",
          "label": "FDA P960009/S219 SSED — Percept PC with BrainSense",
          "date": "2020-06-24"
        },
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "targetUsers": {
      "value": [
        "patient-parkinson",
        "neurologist",
        "neurosurgeon"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    }
  },
  "electrodes": {
    "totalChannels": {
      "value": 8,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "recordingChannels": {
      "value": 8,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "referenceChannels": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "electrodeType": {
      "value": [
        "depth-shaft"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "material": {
      "value": [
        "platinum-iridium"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "positions1020": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "channels": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "requiresGel": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "requiresSaline": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "prepTimeMinutes": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "reusable": {
      "value": false,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "disposable": {
      "value": false,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    }
  },
  "acquisition": {
    "samplingRateHz": {
      "value": {
        "typical": 250
      },
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "resolutionBits": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "notchFiltersHz": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "onboardArtifactRejection": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "stimulation": {
    "capable": {
      "value": true,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    }
  },
  "connectivity": {
    "protocols": {
      "value": [
        "proprietary-rf",
        "bluetooth-le"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "bluetoothVersion": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "bluetoothProfiles": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "concurrentMode": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "encryptionInTransit": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "pairingMethods": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "cloudSync": {
      "value": true,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "offlineRecording": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "power": {
    "sources": {
      "value": [
        "replaceable-other"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "batteryLifeActiveHours": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "chargingPort": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "chargingTimeMinutes": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "batteryReplaceable": {
      "value": false,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "notes": {
      "value": "Non-rechargeable hybrid Ag-vanadium-oxide primary cell. End-of-service requires surgical IPG replacement; battery longevity depends heavily on stimulation parameters.",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    }
  },
  "physical": {
    "weightGrams": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "dimensions": {
      "value": {
        "unit": "mm",
        "length": 68,
        "width": 49,
        "height": 11
      },
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "materials": {
      "value": [
        "titanium",
        "epoxy"
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "sizes": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "headCircumferenceCm": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "operatingTempC": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "compute": {
    "hasOnboardComputer": {
      "value": true,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "operatingSystems": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "primaryOs": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "edgeMlAccelerator": {
      "value": false,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "rootAccessLevel": {
      "value": "none",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "appSandbox": {
      "value": false,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "thirdPartyAppsAllowed": {
      "value": false,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "notes": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "software": {
    "apps": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "mobileApp": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "cloudPlatform": {
      "value": true,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "offlineMode": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "subscriptionRequired": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "rawDataAccess": {
      "value": false,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "exportFormats": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "lslSupport": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "dataOwnership": {
      "value": "manufacturer",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "privacyPolicyUrl": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "sdk": {
    "hasSdk": {
      "value": false,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "docsUrl": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "openSource": {
      "value": false,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "languages": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "webBluetooth": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "rawSampleAccess": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "bciParadigms": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "thirdPartyIntegrations": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "capabilities": {
    "attentionFocus": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "meditationCalm": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "neurofeedback": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "meditationCoaching": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "sleepTracking": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "customCapabilities": {
      "value": [
        {
          "name": "BrainSense chronic LFP recording",
          "description": "Concurrent stim + LFP sensing in human STN/GPi — first commercial DBS to do so.",
          "evidenceLevel": "fda-cleared"
        }
      ],
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/cdrh_docs/pdf/P960009S219b.pdf",
          "label": "FDA P960009/S219 SSED — Percept PC with BrainSense",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    }
  },
  "security": {
    "authenticationFactors": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "perUserProfiles": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "requiresAccount": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "claimingMethods": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "ownershipModel": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "activationLock": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "remoteLock": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "remoteWipe": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "findMyDevice": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "notes": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "firmware": {
    "otaSupported": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "otaTransports": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "updateMechanism": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "updateChannels": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "rollbackSupported": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "signedUpdates": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "forcedUpdates": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "userDeferrable": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "updateRequiresAppCompanion": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "averageUpdateFrequency": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "notes": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "regulatory": {
    "fdaStatus": {
      "value": "pma",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "ceMark": {
      "value": true,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471",
          "label": "Jimenez-Shahed (2021) — Device profile of the Medtronic Percept PC",
          "date": "2021-04-01"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "certifications": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "prescriptionRequired": {
      "value": true,
      "status": "verified",
      "sources": [
        {
          "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009",
          "label": "FDA PMA P960009 — Medtronic DBS family (Activa / Percept lineage; original 1997-07-31, Percept PC supplement S219 approved 2020-06-24)",
          "date": "2020-06-24"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "pediatricApproved": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "pricing": {
    "msrp": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "currentPrice": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "subscription": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "buyUrls": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "warranty": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    },
    "returnPolicyDays": {
      "status": "unknown",
      "updatedAt": "2026-05-04"
    }
  },
  "media": {
    "officialUrl": {
      "value": "https://www.medtronic.com",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.medtronic.com/en-us/healthcare-professionals/products/neurological/deep-brain-stimulation/electrical-stimulation-systems/percept-pc-neurostimulator.html",
          "label": "Medtronic — Percept PC Neurostimulator product page"
        }
      ],
      "updatedAt": "2026-05-04"
    },
    "productPageUrl": {
      "value": "https://www.medtronic.com/en-us/healthcare-professionals/products/neurological/deep-brain-stimulation/electrical-stimulation-systems/percept-pc-neurostimulator.html",
      "status": "verified",
      "sources": [
        {
          "url": "https://www.medtronic.com/en-us/healthcare-professionals/products/neurological/deep-brain-stimulation/electrical-stimulation-systems/percept-pc-neurostimulator.html",
          "label": "Medtronic — Percept PC Neurostimulator product page"
        }
      ],
      "updatedAt": "2026-05-04"
    }
  },
  "editorial": {
    "pros": [
      "Only DBS with chronic, in-vivo LFP sensing in cleared use",
      "3T full-body MRI conditional",
      "Directional-lead capable (with SenSight)"
    ],
    "cons": [
      "Non-rechargeable IPG — requires surgical replacement",
      "Adaptive (closed-loop) DBS not yet enabled on PC variant in US",
      "Cloud is closed; raw LFPs only accessible via Medtronic tools"
    ],
    "bestFor": [],
    "notFor": [],
    "comparableDevices": [
      "boston-scientific-vercise-genus",
      "abbott-infinity-dbs",
      "neuropace-rns"
    ]
  },
  "provenance": {
    "sources": [
      {
        "label": "FDA PMA P960009 database",
        "url": "https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P960009"
      },
      {
        "label": "FDA P960009/S219 SSED — Percept PC",
        "url": "https://www.accessdata.fda.gov/cdrh_docs/pdf/P960009S219b.pdf"
      },
      {
        "label": "Jimenez-Shahed (2021) Percept PC device profile",
        "url": "https://www.tandfonline.com/doi/full/10.1080/17434440.2021.1909471"
      },
      {
        "label": "Medtronic Percept PC product page",
        "url": "https://www.medtronic.com/en-us/healthcare-professionals/products/neurological/deep-brain-stimulation/electrical-stimulation-systems/percept-pc-neurostimulator.html"
      }
    ],
    "lastReviewedAt": "2026-05-05"
  }
}